Freestanding mock-ups to compare passive and active heating, plus a cold frame. Drag to orbit, pinch or scroll to zoom. Sized and noted for Brentwood Bay winters — mild, cloudy, with the odd −5 °C snap. Nothing here is a plan yet; it's for talking over.
At 48.6°N the Dec 21 sun culminates at about 18° altitude due south — that's why the passive designs face their glazing south and keep the north side solid.
All four designs side by side — qualitative only, on a −4 °C night.
| Design | Heat source | On a −4 °C night | Build effort | Running cost |
|---|---|---|---|---|
| Chinese passive solar | Sun + brick mass wall + night blanket | Strongest passive hold | High — masonry build | Nil, but a daily blanket ritual |
| Hoop house | Water barrels, optional wood stove | A few °C above outside; stove nights much warmer | Low | Nil to firewood |
| Hartley cold frame | Glazing alone, jugs, hotbed or 75 W cable | 2–4 °C above outside; cable holds soil temp exactly | None — buy it; premium price for a cold frame | Nil to pennies |
| Hartley Grand Classic | Thermal battery under the floor — south-rack collectors + PV-fed immersion elements | ≈3 frost-free nights per full charge, through floor loops | Low effort, high spend on the shell; the hydronics are a project | Sun + pumping watts; no fuel bill |
The comparison above mixes sizes and heat sources, which isn't a fair fight. This one normalises both: every design is scaled to the same growing space and handed the same heating system, so what remains is pure envelope — how fast each shape leaks heat. Then stress it: set the cold snap, the tank and the charge temperature, and read off the outputs that matter — how many days the heat lasts, and how steady the temperature stays at the roots and in the air.
| Design | Heat loss | Loss per m² | Night kWh | Cold-snap endurance | Coldest air | Root-zone swing |
|---|
*A "night" is 14 hours at the snap temperature; endurance runs the snap around the clock with no sun — the worst case. Method: envelope areas are scaled from the models above, proportions unchanged. U-values (W/m²°C): single glass 5.8, single poly film 5.8, blanket-covered glazing 1.8, and 1.0 for the Chinese design, whose blanket now sits over double-glazed units — its night blanket is part of the design, and nights are when heating happens — insulated opaque 0.5–0.6, light opaque 1.5–2.5; plus a per-design allowance for frame, ground contact and air leakage (the film house leaks most). Calibrated so the Grand Classic lands on its ≈290 W/°C and the cold frame on its ≈30 W/°C from their notes. The battery's usable energy is its water × the swing between the charge temperature and ≈30 °C, below which it can no longer drive floor loops. Stability figures are typical control behaviour: floor loops hold air within about a degree and the root zone — sitting on the radiator — within ≈0.5 °C; a fan heater cycles the air ≈4 °C while the roots, heated only through the air, average that to ≈1.5 °C; unheated, air and roots follow the design's thermal-mass curve, the roots lagging the air roughly 2.5×. Scaling the cold frame up is a thought experiment in shape, not a product suggestion. Estimates for comparison, not engineering figures.
Endurance is only half the question — the other half is whether the sun can put the charge back. This table runs each month's average weather at this latitude (48.6°N, Victoria) against each design: the harvest from the 4.8 kWp PV array and the ≈4 m² collector rack, minus what the house burns holding temperature through that month's nights. It uses the growing space, hold temperature, battery water and charge temperature set in the comparison above; the cold-snap slider doesn't apply here — this is average weather, not a snap.
In winter the PV does the heavy lifting: a flat-plate collector trying to make 55 °C water on a 0 °C day runs poorly, while the immersion elements don't care what month it is — the last degrees of a winter charge are mostly a PV story. From April to September the question inverts: everything fills within days and then sits full, and the design problem becomes the opposite one — a diverter with nowhere to send power, and collectors that need stagnation handling (drainback earns its keep). And the timing is unkind: a full battery is cold-snap insurance, and the months a snap can actually arrive are the very months a leaky envelope can't refill it.
Where the table below shows ✗, the gap is only a few kWh a day — and that is what the wood boiler stove in the viewer is for. It's a water-jacket stove plumbed straight into the store, burned in the evening to charge the battery rather than to heat the air (some radiant warmth in the room is unavoidable, but it's the side effect, not the job). At ≈6 kW to water, a three-hour burn banks ≈18 kWh — several December deficit days for the Grand Classic in one firing, and a way to refill after a snap while the sun is still too weak to help. It is also the one source that doesn't care about the weather forecast. The one rule it imposes: a wood fire can't be switched off, so the store must be open-vented or have a heat-dump path — the floor loops double as the dump — and never sealed against a boiling jacket.
| Month | Harvest / day | Chinese passive solar | Hoop house | Cold frame | Grand Classic |
|---|
✓ fills from empty within the month (figure = days it takes) · ~ gains charge, but slower than the month (figure = daily surplus) · ✗ loses charge in average weather (figure = daily deficit). PV harvest: PVGIS month-by-month figures for Victoria (39 kWh per kWp in December, 167 in July) × 4.8 kWp. Collectors: estimated for 4 m² of flat plate at 55° tilt, ≈1.7 kWh/day in December rising to ≈10 in July. Monthly burn: each design's heat loss × the month's effective heating degrees — a day/night integration against the hold temperature using Victoria's monthly mean temperatures, so frost nights count even in months whose average is mild. "From empty" means from the ≈30 °C floor to the charge temperature set above; in practice the store enters most months part-charged, so real fills are quicker than the table's worst case.
Researched Nov 25, 2026. The figure that matters for this job is the split: how much of the output goes to water (into the battery) versus to the room (onto the plants). Prices are as listed by the sellers, in pounds or euros — none of these sellers states shipping to Canada, and certification for use here is a separate question to settle before any of it is real.
Boiler stoves are room heaters with a water jacket, so some heat to the room is by design. Dedicated wood boilers are the pure form: an insulated plant-room appliance that sends essentially everything to water and is built to burn flat-out into a thermal store, then go out.
| Unit | Class | To water | To room | Price as listed |
|---|---|---|---|---|
| Hi-Flame Aidan Eco — The Stove Yard | Boiler stove, cast iron, 223 kg | 12.5 kW | 4.5 kW | £1,795 |
| Henley Sherwood 21 — Direct Stoves | Boiler stove, multifuel | 13 kW | 8.1 kW | £1,599 (list £2,200) |
| Woodfire EX15 — Stoves Are Us | Inset boiler stove — built into a wall | 12.5 kW | 2.5 kW | £4,450 |
| Atmos GS 15 — Das Holzofenkontor | Dedicated gasification boiler (GS range 15–40 kW) | ≈15 kW (all of it) | ~nil | €3,973 |
| Garn WHS — Canadian dealer: Rocky Mountain Solar | Dedicated boiler, firebox inside its own tank | all of it | ~nil | via dealer |
Notes on the fit: the Aidan Eco has the best water fraction of the freestanding stoves (about 69%) and the least unwanted room heat. The Sherwood is stronger and cheaper but pours 8.1 kW into the room — a liability in a small greenhouse on a long burn. The EX15 is the interesting one for the Chinese design specifically: it's an inset, made to be built into a wall exactly as the model now shows, with the leanest room output of any stove here (its bigger sibling, the EX22, offers 18.5 kW to water). The Atmos class — Fröling and ETA are the premium equivalents — is the pure answer: ~90% efficiency, batch burns into the store, nothing asked of the room. The Garn is that idea taken to its limit, the firebox inside a 1,500–3,200 US-gallon tank; it's oversized for one greenhouse, but it's the one unit here with a Canadian dealer. A dozen other boiler stoves were checked and dropped: their headline numbers are total output, with only 4–7 kW reaching the water.
Sizing the burn — one load, by design. The safe way to pair a wood boiler with a store is to size them together: the store must swallow one full firebox load, starting from its alert temperature, without passing its ceiling. Then the fuel load itself is the safety limit — light it, walk away, and the fire dies when it's done; there is nothing to throttle and nothing to watch. With a 10 °C “empty” alert and a 30 °C ceiling (a 20-degree window), the standard 5,900 L store absorbs ≈137 kWh — one load of ≈39 kg of seasoned wood, which is what a ≈125 L firebox (Atmos GS 25 class) holds. The Chinese design's ≈9,200 L store takes ≈61 kg. Rule of thumb: ≈150 litres of store per kilo of wood in the load, per 20 degrees of window. The warning bands fall out of the same arithmetic: 30 °C full · 20 °C low (half the window left — burn when convenient) · 10 °C empty (burn tonight).
The low band is also the efficient band. Heat transfer follows the temperature gap between source and store: a boiler flowing at ≈75 °C into a 10 °C store charges at full tilt, and at the 30 °C ceiling the gap is still ≈45 degrees, so the rate has only eased to roughly 70%. Push the store toward 55–70 °C and the gap collapses — the last degrees are the slowest from the boiler, and worse from the solar collectors, whose efficiency falls steadily the hotter they must run. A 30 °C ceiling keeps every source in its efficient range.
The two Hartley designs above are modelled from the manufacturer's own pages — photos of the actual products: